Conventional Power Materials

Covering low-loss Mn-Zn ferrites for switching power supplies, as well as dedicated grades for new energy and high-frequency applications.

MC.TECH / MATERIALS
01 CATEGORY OVERVIEW

Materials

Low-loss Mn-Zn ferrites for switching power supplies, covering 100kHz-class main power conversion. High-permeability grades are suitable for small-size, high-inductance designs, while high-Bs / high-Tc grades target high-temperature, high-current applications.

CONVENTIONAL POWER / 7 GRADES
01 CONVENTIONAL POWER

Conventional Power Materials

Low-loss Mn-Zn ferrites for switching power supplies, covering 100kHz-class main power conversion. High-permeability grades are suitable for small-size, high-inductance designs, while high-Bs / high-Tc grades target high-temperature, high-current applications.

Power loss Pcv: typical values (kW/m³) at 25/80/100/120℃ under B=200mT, f=100kHz sine wave.

Grade  Initial permeability μiTYP. ±25% Power loss PcvkW/m³ (25/80/100/120℃) Saturation flux density BsmT Remanence BrmT Coercivity HcA/m Curie temperature Tc℃ Resistivity ρvΩ·m
2300 ±25%600/430/410/500510390 142156.5
2400 ±25%600/350/310/400510400 132156.5
2500 ±25%600/330/280/360530410 132305
2200 ±25%700/380/350/420540450 142555
3300 ±25%350/280/290/350530420 122206.5
3300 ±25%290/265/290/330530430 122207
3500 ±25%260/280/310/350530410 102307
02 HIGH PERMEABILITY

High Permeability Materials

High-permeability ferrites with initial permeability of 5500–15000, for common-mode chokes, signal transformers and EMI filtering. The KW series retains high μi from several hundred kHz to 1MHz, suitable for wireless charging and high-frequency filtering.

Grade  Initial permeability μiTYP. ±25% Relative loss factor tanδ/μi×10⁻⁶ · 100kHz Saturation flux density BsmT Remanence BrmT Coercivity HcA/m Curie temperature Tc℃ Resistivity ρvΩ·m
5500 ±25%15 (100kHz)41065 6>1400.3
7500 ±25%30 (100kHz)41065 5>1300.2
10000 ±25%30 (100kHz)40070 3>1200.2
12000 ±25%30 (100kHz)39080 6>1150.15
15000 ±25%80 (100kHz)360100 5>1100.15
5500 ±25% (3000 @1MHz)<10 (100kHz)43070 6>1501
7000 ±25% (3500 @800kHz)<15 (100kHz)43080 6>1500.3
10000 ±25% (9500 @200kHz)<20 (100kHz)410100 5>1300.2
03 HIGH-FREQUENCY POWER

High-Frequency Power Materials

Low-loss ferrites for 100kHz–3MHz power conversion. Typical applications include fast-charging adapters, high-frequency power supplies, and power magnetic components for automotive and communication equipment.

Grade  Initial permeability μiTYP. ±25% Loss index  Frequency range  Saturation flux density BsmT Curie temperature Tc℃ Resistivity ρvΩ·m
2000 ±25%Pcv 200 (200kHz·125mT)100–200kHz 45020020
1400 ±25%Pcv 130 (500kHz·50mT)100–500kHz 47023030
900 ±25%Pcv 150 (1MHz·50mT)0.5–3MHz 48028030
900 ±25%Pcv 90 (1MHz·50mT)1–3MHz 53028030
04 HIGH-FREQUENCY IMPEDANCE

High-Frequency Impedance Materials

High-impedance iron-deficient materials for 1–100MHz, with low relative loss factor and high normalized impedance Z. Typical applications include EMI suppression, signal-line filtering and anti-interference magnetic components.

Grade  Initial permeability μiTYP. ±25% Relative loss factor tanδ/μi×10⁻⁶ · 10kHz Normalized impedance ZΩ/mm · 1/25/100MHz Frequency rangef Saturation flux density BsmT Curie temperature Tc℃ Resistivity ρvΩ·m
1000 ±25%tanδ/μi <45 (10kHz)4/40/120 (1/25/100MHz)1–100MHz 430>1800.3
2000 ±25%tanδ/μi <35 (10kHz)8/50/110 (1/25/100MHz)1–100MHz 410>1500.2
3000 ±25%tanδ/μi <30 (10kHz)9/50/110 (1/25/100MHz)1–100MHz 390>1300.2
4000 ±25%tanδ/μi <15 (10kHz)10/50/110 (1/25/100MHz)1–100MHz 340>1100.15

* Typical values; Bs / Br / Hc measured at H=1194 A/m; power loss Pcv measured under B=200mT, f=100kHz sine wave (high-frequency grades at their corresponding test frequency); high-permeability material loss is tanδ/μi (×10⁻⁶, 100kHz); MZ series tested on a T25-15-7.5 toroid.